THE CHARACTERISTIC OF EXTERNAL FIXATION APPARATUS SYSTEMS, USED IN THE TREATMENT OF DIAPHYSIAL FRACTURES OF THE LONG BONES (COMPARATIVE EVALUATION OF MOBILITY BETWEEN THE SPLINTERS)
Abstract
The article is devoted to the history, development of method improvement of transosseous osteosynthesis and approaches of the authors to external fixation of bone fragments. The analysis of osteosynthesis has been conducted. There have been presented the positive and negative aspects of the method, the differences of various designs of external fixation devices, from the core units to the spoke-rod devices. The evaluation of the stability of fixation of bone fragments in the system of “device-bone” has been given. The new trends of development of transosseous osteosynthesis method have been shown. The experimental researches of stiffness of fragments fixation in the devices of the author have been performed.
References
2. Волков М.В., Оганесян О.В. Восстановление формы и функции суставов и костей (аппаратами авторов). - М.: Медицина, 1986. - 256 с.
3. Голубев Г.Ш.у Кривец Д.В. Возможности контроля стабильности аппарата и управления биомеханическим режимом при компрессионно-дистракционном остеосинтезе // Бюллетень Восточно-Сибирского научного центра СО РАМН. - 1994. - №1. - С.25-29.
4. Гудушаури О.Н., Оганесян О.В. Внеочаговый компрессионный остеосинтез при закрытых диафизарных переломах и ложных суставах костей голени. - М.: Медицина, 1968. - 103 с.
5. Зедгенидзе ИВ., Виноградов В.Г., Печенюк В.И. и др. Аппарат внешней фиксации для лечения переломов и ложных суставов длинных костей: пат. 2152765 Рос. Федерация: МКИ А61В 17/66 / заявитель и патентообладатель Иркутский государственный медицинский университет. - № 98111383/14; заявл. 09.06.1998; опубл. 30.07.2000, Бюл. № 20. - 1 с.
6. Зедгенидзе И.В., Домаьиевский Б.А., Клименко И.Г. Аппарат внешней фиксации для лечения переломов и ложных суставов длинных костей: пат. 2140773 Рос. Федерация: МКИ А61В 17/66 / заявитель и патентообладатель Иркутский государственный медицинский институт Минзравмедпрома РФ. - № 97114091/14; заявл. 18.08.1997; опубл. 10.11.1999, Бюл. № 31. - 1 с.
7. Илизаров Г.А. Чрескостный компрессионный остеосин¬тез аппаратом автора: Дисс... канд. (д-ра) мед. наук. - Курган, 1968. - 483 с.
8. Калнберз В.К., Студерс П.Я., Добелис М.Я. Сравнительное исследование жесткости спиц Киршнера, стержней Штейнмана и винтов Шанца в идентичных экспе-риментальных условиях и в клинике // Ортопедия и травматология. - 1988. - №12. - С. 16-19.
9. Розен Л.А. II Вестник хирургии и пограничных областей. - 1926. - Т. 6. №16. - С.83.
10. Рынденко В.Г, Маковоз Е.М., Бэц Г.В., Михайлов С.Р. Внеочаговая фиксация отломков костей стержневыми аппаратами с позиций биомеханики и клиники // Политравма. - Харьков, 1986. - С. 122-124.
11. Соломин Л.Н. Управляемый комбинированный остео-синтез длинных костей: разработка, обоснование, клиническое использование: Дис. ... д-ра мед. наук. - Иркутск, 1996. - 348 с.
12. Ткаченко С. С., Гайдуков В.М. Компрессионно- дистракционный аппарат одноплоскостного действия // Ортопедия, травматология и протезирование. - 1986. - №4. - С.57-58.
13. Шевцов В.И, Немков В.А., Скляр JI.B. Аппарат Илизарова // Биомеханика. - Курган, 1995. - 164 с.
14. Anderson R.J. II Internal College Surg. - 1942. - Vol. 5. - P.458.
15. Hoffmann G. Monitoring fracture site properties with external fixation // Acta Traumatol. - 1982. - Vol. 12. №2. - P.62- 40
16. Hoffmann R. II Acta chir. Scand. - 1942. - Vol. 86. - P.235.
17. Hoffmann R. II Helvetica chir. Acta. - 1953. - Vol. 20. - P.487.
18. Hoffmann R. II Acta Chir. Scand. - 1954. - Vol. 107. №1. - P.72.
19. Hoffmann R. II Lyon Chir. - 1955. - Vol. 50. - P.309.
20. Hoffmann R. II Acta Chir. Belg. - 1957. - Vol. 56. - P.585.
21. Key J. II Surgery. - 1937. - Vol. 1. - P.730.
22. LambotteA. Un cas heureux d’intervention pour retraction progressive del’aponeurose // J. Chir. - 1902. - Vol. 11. - P.207- 210.
23. Malgaiyne J. Cited from Alfredo Ceballos Mesa / Malgaigne // In 1840,1843.
24. Stader О. II North Am. Veter. - 1937. - Vol. 18. №1. - P.37.
25. Stader О. II North Am. Veter. - 1937. - Vol. 18. №1. - P.52.
REFERENCES
1. Vvedensky S.P. Device to eliminate the angular deformations of the hip // Ortopediya i travmatologiya. - 1978. - №8. - P.71-72. (in Russian)
2. Volkov M.V., Oganesyan O.V. Restoration of the form and function of the joints and bones (of authors). - Moscow: Medicine, 1986. - 256 p. (in Russian)
3. Golubev G.S., Krivets D.V. Control stability of the apparatus and control of the biomechanical mode during compression- distraction osteosynthesis // Acta Biomedica Scientifica. - 1994. - №1. - P.25-29. (in Russian)
4. Gudushauri O.N., Oganesyan O.V. Neocolony compression osteosynthesis of closed diaphyseal fractures and false joints of Shin bones. - Moscow: Medicine, 1968. - 103 p. (in Russian)
5. Zedgenidze I. V., Domashevskyj V.A., Klimenko I. G. External fixation apparatus for the treatment of fractures and false joints of long bones: Pat. 2140773 grew up. Federation: BIM and 61 in 17/66/; applicant and patentee Irkutsk State Medical University Minzravmedproma of the Russian Federation. -# 97114091/14; Appl. 18.08.1997; in English. 10.11.1999, Director. No. 31.1 p. (in Russian)
6. ZedgenidzeI.V., Vinogradov, V. Pechenuk V.I., etal. External fixation apparatus for the treatment of fractures and false joints of long bones: Patent 2152765 Russian Federation: BIM and 61 in 17/66/; applicant and patentee Irkutsk State Medical University. -# 98111383/14; Appl. 09.06.1998; in English. 30.07.2000, Director. No. 20.1 p. (in Russian)
7. Ilizarov G. A. Transosseous compression osteosynthesis apparatus author: Thesis DSc (Medicine). - Kurgan, 1968. - 483 p. (in Russian)
8. Kalnberz V. K, Studers P. J., Dobelis M.J. Comparative study of the stiffness of the spokes of Kirchner, Steinman rods and screws Trench in identical experimental conditions and in the clinic // Ortopediya i travmatologiya. - 1988. - №12. - P.16-19. (in Russian)
9. Rosen L.A. II Vestnik khirurgii i pogranichnykh oblastey. - 1926. - Vol. 6. №16. - P.83.
10. Ryndenko V.G., Makovoz E.M., Behc G.V., Mikhailov S.R. In the fixation of fragments of bones core devices from the standpoint of biomechanics and clinic // Polytrauma. - Kharkov, 1986. - P.122-124. (in Russian)
11. Solomin L.N. Managed combined osteosynthesis of long bones: development, rationale, clinical use: Thesis DSc (Medicine). - Irkutsk, 1996. - 348 p. (in Russian)
12. Tkachenko S.S., Gaidukov V.M. Compression-distraction apparatus is flushed action // Ortopediya, travmatologiya i protezirovaniye. - 1986. - №4. - P.57-58.
13. Shevtsov V.I., Nemkov V.A., Sklyar L.V. Biomechanics of the Ilizarov’s Apparatus. - Kurgan, 1995. - 164 p.
14. Anderson R.J. II Internal College Surg. - 1942. - Vol. 5. - P.458.
15. Hoffmann G. Monitoring fracture site properties with external fixation // Acta Traumatol. - 1982. - Vol. 12. №2. - P.62- 68.
16. Hoffmann R. II Acta chir. Scand. - 1942. - Vol. 86. - P.235.
17. Hoffmann R. II Helvetica chir. Acta. - 1953. - Vol. 20. - P.487.
18. Hoffmann R. II Acta Chir. Scand. - 1954. - Vol. 107. №1. - P.72.
19. Hoffmann R. II Lyon Chir. - 1955. - Vol. 50. - P.309.
20. Hoffmann R. II Acta Chir. Belg. - 1957. - Vol. 56. - P.585.
21. Key J. // Surgery. - 1937. - Vol. 1. - P.730.
22. LambotteA. Un cas heureux d’intervention pour retraction progressive del’aponeurose // J. Chir. - 1902. - Vol. 11. - P.207- 210.
23. Malgaiyne J. Cited from Alfredo Ceballos Mesa / Malgaigne // In 1840,1843.
24. Stader О. II North Am. Veter. - 1937. - Vol. 18. №1. - P.37.
25. Stader O. // North Am. Veter. - 1937. - Vol. 18. №1. - P.52.

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.